High performance general purpose mini drive
(V/F mode / Sensorless Vector mode)
1-Phase, 110V : 0.2-0.75kW (0.25-1Hp)
1-Phase, 230V : 0.4-2.2kW (0.5-3Hp)
3-Phase, 230V : 0.4-3.7kW (0.5-5Hp)
3-Phase, 460V : 0.75-3.7kW (1-5Hp)
Features
16 Bit Microprocessor Sensor less vector control
V/F mode & Sensor less Vector mode
Auto tuning
Over load capability 150%, 1 minute
Automatic torque boost & slip compensation
Output frequency 0.1~600Hz, Programmable
16-step PLC run & 16 step preset speed
PID feedback control & PG feedback control
2 accel./decel time selection (0.01~60000 sec)
Pump control and automatic energy -saving.
Process follower - 10~10VDC, 0~10VDC, 4~20mA
MODBUS communication RS-485 (Baud rate 125000 bps) (optional)
Coast or ramp to stop
Random V/F curve & Automatic voltage regulation (AVR)
Auto-optimum accel./decel. time & S-curves
Sleep/Wakeup function & Auto Restart after fault
Mechanical braking release control function
Auto Restart after fault & Fault history up to 16 records
Module/ Heatsink temperature display & Pre-warning
Low noise-- Carrier frequency up to 18 kHz
Bi-Directional Speed search (Reentry to spinning load)
Password protection & User define Multi-function display
DC bus capacitor life time monitoring & Auto carrier frequency adjust
Over-current/Over-voltage stall prevention & Over torque detection
Full protection (LV,OV,OC,SC,OH,OL...etc.)
Programmable Multi-Function input terminals
Programmable Multi-Function output terminals
Programmable Analog output voltage & current signals (optional)
Programmable Digital pulse output (optional)
Encorder style knob with 0.01Hz resolution
Removable Keypad operator up to 150 meters.
DC injection brake & Dynamic brake
Electronic Thermal Relay & External Counter built-in
Easy DIN rail mounting
Versatile control I/O configuration & Customization I/O interface
Model Names
Topvert S1 Series: 1-Phase, 100-120VAC, 50/60 Hz (Tolerance Range: 90-132V, 47-63Hz)
(Output: 200-240VAC) |
Model |
Applicable Motor
(230V, 4 Pole) |
Rated Output |
Power Source |
Enclosure Construction |
S1-xxxxx |
Power
(kW) |
Horse Power (Hp) |
Capacity
(kVA) |
Current
(A) |
Voltage
(V) |
Frequency
(Hz) |
Current
(A) |
Cooling Methods |
Protection |
Weight Net/Gross
(kg) |
Cubic
(CBM) |
Frame Code |
110P2 |
0.2 |
0.25 |
0.6 |
1.6 |
3-Phase
0-240 (Max.) |
0.1~600 |
6.1 |
Fan-cooled |
IP 20
|
|
0.0054 |
S1-A
|
110P4 |
0.4 |
0.5 |
1.2 |
3 |
11.4 |
|
110P7 |
0.75 |
1 |
2 |
5 |
19.1 |
|
Topvert S1 Series: 1-Phase, 200-240VAC, 50/60 Hz (Tolerance Range: 180-264V, 47-63Hz) |
Model |
Applicable Motor
(230V, 4 Pole) |
Rated Output |
Power Source |
Enclosure Construction |
S1-xxxxx |
Power
(kW) |
Horse Power (Hp) |
Capacity
(kVA) |
Current
(A) |
Voltage
(V) |
Frequency
(Hz) |
Current
(A) |
Cooling Methods |
Protection |
Weight Net/Gross
(kg) |
Cubic
(CBM) |
Frame Code |
210P4 |
0.4 |
0.5 |
1.2 |
3 |
3-Phase
0-240 (Max.) |
0.1~600 |
5.7 |
Fan-cooled |
IP 20
|
1.0/1.2 |
0.0054 |
S1-A
|
210P7 |
0.75 |
1 |
2 |
5 |
9.5 |
1.0/1.2 |
211P5 |
1.5 |
2 |
3 |
7.5 |
14.3 |
1.2/1.5 |
(212P2) |
2.2 |
3 |
4.4 |
11 |
|
|
|
(S1-B) |
Topvert S1 Series: 3-Phase, 200-240VAC, 50/60 Hz (Tolerance Range: 180-264V, 47-63Hz) |
Model |
Applicable Motor
(230V, 4 Pole) |
Rated Output |
Power Source |
Enclosure Construction |
S1-xxxxx |
Power
(kW) |
Horse Power (Hp) |
Capacity
(kVA) |
Current
(A) |
Voltage
(V) |
Frequency
(Hz) |
Current
(A) |
Cooling Methods |
Protection |
Weight Net/Gross
(kg) |
Cubic
(CBM) |
Frame Code |
230P4 |
0.4 |
0.5 |
1.2 |
3 |
3-Phase
0-240 (Max.) |
0.1~600 |
3.3 |
Fan-cooled |
IP 20
|
1.0/1.2 |
0.0054 |
S1-A
|
230P7 |
0.75 |
1 |
2 |
5 |
5.5 |
1.0/1.2 |
231P5 |
1.5 |
2 |
3 |
7.5 |
8.3 |
1.2/1.5 |
(232P2) |
2.2 |
3 |
4.4 |
11 |
12.1 |
|
|
(S1-B) |
(233P7) |
3.7 |
5 |
6.8 |
17 |
|
|
Topvert S1 Series: 380 ~ 460VAC
, 50/60 Hz (Tolerance Range:
342 ~ 528V,47 ~ 63Hz
) |
Model |
Applicable Motor
(460V, 4 Pole) |
Rated Output |
Power Source |
Enclosure Construction |
S1-xxxxx |
Power
(kW) |
Horse Power (Hp) |
Capacity
(kVA) |
Current
(A) |
Voltage
(V) |
Frequency
(Hz) |
Current
(A) |
Cooling Methods |
Protection |
Weight Net/Gross
(kg) |
Cubic
(CBM) |
Frame Code |
430P4 |
0.4 |
0.5 |
1.3 |
1.6 |
3-Phase
0-460 (Max.) |
0.1~600 |
1.8 |
Fan-cooled |
IP 20
|
|
0.0054 |
S1-A
|
430P7 |
0.75 |
1 |
2.4 |
3 |
3.3 |
|
431P5 |
1.5 |
2 |
3.3 |
4.2 |
4.6 |
|
432P2 |
2.2 |
3 |
4.8 |
6 |
6.6 |
|
|
(S1-B) |
433P7 |
3.7 |
5 |
6.8 |
8.5 |
|
|
Remark: ( )means not available.
Specifications
Max. Applicable Motor
Output Range (kW/Hp) |
1- phase, 100 ~ 120VAC, 50/60Hz:0.2 ~ 0.75kW (0.25 ~ 1Hp) |
1- phase, 200 ~ 240VAC, 50/60Hz:0.4 ~ 2.2kW (0.5 ~ 3Hp) |
3-phase, 200 ~ 230VAC, 50/60Hz:0.4 ~ 3.7kW (0.5 ~ 5Hp) |
3-phase,380 ~ 460VAC, 50/60Hz:0.4 ~ 3.7kW (0.5~ 5Hp) |
Output |
Output Frequency |
0.1 ~ 600Hz |
Overload Endurance |
150% of rated current for 1 minute/10minute, Ta <=40 ; 200% of rated current for 2 seconds |
Maximum Output Voltage |
Proportional to Input Voltage, 3-Phase (For 100V class, output voltage is twice of the input voltage) |
Power factor / Efficiency |
Power factor no lower than 0.95. Efficiency no lower than 95% at full load |
Control Characteristics |
Control System |
SPWM (Sinusoidal Pulse Width Modulation), V/F control and Sensorless Vector Control selectable
|
Speed Control |
V/F Control 1:20; Sensorless Control 1:50
|
Frequency Setting Range |
0.10 - 600Hz,programmable |
Frequency Setting Resolution |
0.01Hz/step |
PWM Carrier Frequency |
1kHz - 18kHz Adjustable (Restrictions on some models) |
Torque Characteristics |
Including the auto-torque, auto-slip compensation; starting torque can be 150% at 1.0Hz
|
Skip Frequency |
3 points |
Accel/Decel Time |
0.1-6000 seconds (2 Independent settings for Accel/Decel Time) |
Stall Prevention Level |
10 to 250%, Setting of Rated Current. Setting range 0.1-600Hz while stop |
DC Braking |
DC Braking Current Level: 0 to 125% of rated output current. DC Braking time: 0 to 60 seconds. Start-Point for DC Braking: 0.1-600Hz both when start up and stop.
|
Dynamic Braking Torque |
Approx. 20%, Dynamic Brake chopper built-in. |
V/F Pattern |
Adjustable V/F curve using 4 independent points. |
Operating Characteristics |
Frequency Setting |
Keypad |
By a rotary encoder (setting resolution 0.01Hz/step) |
External Signal |
0 ~ +10VDC (Input impedance 20k Ω ), 4 ~20mA DC ( Input impedance 250 Ω ), Multi-Function Inputs 1 ~ 6 (15 Steps Jog, up/down ), PLC run , (Option) RS-485 serial interface MODBUS protocol |
Operation Setting |
|
Set by RUN and STOP key |
External Signal |
FWD, REV, MI1 to MI6 can be combined to offer various modes of operation, (Option) RS-485 serial interface MODBUS protocol |
Multi-Function Input Signal
(4 signals) |
Multi-step selection 0 to 15, first to second accel/decel switches, accel/decel inhibit, EF Input, Emergency Stop, auxiliary motor control is invalid, ACI/AVI/AUI speed command selection, Reset, PLC Run , Jog, Up/Down command
|
Multi-Function Output Indication |
Drive Operating, Frequency Attained, Non-zero, Base Block, Fault Indication,Local/Remote indication, PLC Operation indication, and Auxiliary Motor Output
|
Analog Output Signal (option) |
Analog signal output proportional to output frequency, output current, voltage, frequency command or motor's speed. |
Fault Indication |
The output will be activated when faults occur |
Communication |
(Option) RS-485 serial interface MODBUS protocol |
|
PID feedback control, automatic voltage regulation, Momentary Power Loss restart, S-Curve, External Fault, Fault Reset, Auto Restart, Fault Records, Frequency Limits,Fan & Pump Control, Parameter Lock/Reset, Auto Tuning, Reverse Inhibition, Over-Voltage/ Over-Current Stall Prevention, automatic energy-saving, DC Braking, Speed Search during Start-up, PLC, MODBUS Communication |
|
Self-testing, AC source Over Voltage, Over Voltage, Over Current, Under Voltage, Over Load, Overheating, External Fault, Electronic thermal, Ground Fault, Stall Prevention, Output short circuit , IGBT short circuit |
Digital Keypad
(6 digits, undetachable)
|
6 Function keys |
Access Run, Stop, Reset/ Digit Shift, Display mode, Keypad Enable, Programming data operation. |
360 degree Rotary Encoder |
Sets the parameter number and changes the numerical data |
6 digits 7 segment display |
Display the Setting frequency/actual operation frequency, Output current/Voltage, User defined unit. |
Six LED Display for status indication |
Display the AC drive's run/stop status, forward/Reverse run status, Keypad enable, and Frequency command source. |
|
CE Safety |
Meet LVD: EN50178 standards; When combining with Toptek's filter, meet EMC: EN61800-3 standards
|
UL Safety |
Meet UL508C standards |
Temperature |
Ambient: -10°C ~ +40 °C ( Non-Condensing and not frozen ). Storage: -20°C ~ +60° C |
Humidity |
Below 98% R. H. (Non-Condensing) |
Vibration |
Below 20Hz: 1G, above 20Hz: 0.6G |
Installation Location |
Altitude 1,000 m or lower, keep away from corrosive gasses, liquid and dust |
|