HOME > Product > AC Motor Drive > Topvert E1 series Frequency Inverter

Topvert E1 Series AC Motor Drive

High performance general purpose compact drive
(V/F mode / Sensorless Vector mode)

110V, 1-Phase : 0.2-1.5kW (0.25-2Hp)
230V, 1-Phase : 0.2-2.2kW (0.25-3Hp)
230V, 3-Phase : 0.4-7.5kW (0.5-10Hp)
460V, 3-Phase : 0.4-7.5kW (0.5-10Hp)

Features

  • 16 Bit Microprocessor Sensor less vector control
  • V/F mode & Sensor less Vector mode
  • Auto tuning
  • Over load capability 150%, 1 minute
  • Automatic torque boost & slip compensation
  • Output frequency 0.1~600Hz, Programmable
  • 16-step PLC run & 16 step preset speed
  • PID feedback control & PG feedback control
  • 2 accel./decel time selection (0.01~60000 sec)
  • Pump control and automatic energy -saving.
  • Process follower - 10~10VDC, 0~10VDC, 4~20mA
  • MODBUS communication RS-485 (Baud rate 125000 bps) (optional)
  • Coast or ramp to stop
  • Random V/F curve & Automatic voltage regulation (AVR)
  • Auto-optimum accel./decel. time & S-curves
  • Sleep/Wakeup function & Auto Restart after fault
  • Mechanical braking release control function
  • Auto Restart after fault & Fault history up to 16 records
  • Module/ Heatsink temperature display & Pre-warning
  • Low noise-- Carrier frequency up to 18 kHz
  • Bi-Directional Speed search (Reentry to spinning load)
  • Password protection & User define Multi-function display
  • DC bus capacitor life time monitoring & Auto carrier frequency adjust
  • Over-current/Over-voltage stall prevention & Over torque detection
  • Full protection (LV,OV,OC,SC,OH,OL...etc.)
  • Programmable Multi-Function input terminals
  • Programmable Multi-Function output terminals
  • Programmable Analog output voltage & current signals (optional)
  • Programmable Digital pulse output (optional)
  • Encorder style knob with 0.01Hz resolution
  • Removable Keypad operator up to 150 meters.
  • Sink/Source (NPN/PNP) mode selectable by user
  • DC injection brake & Dynamic brake
  • Electronic Thermal Relay & External Counter built-in
  • Easy DIN rail mounting
  • Model Names

    Topvert E1 Series: 1-Phase, 100-120VAC, 50/60 Hz (Tolerance Range: 90-132V, 47-63Hz)

    Output: 200-240VAC

    Model

    Motor

    (230V, 4 Pole)

    Rated Output

    Power Source

    Enclosure Construction

    E1-xxxxx

    Power

    (kW)

    Horse Power (Hp)

    Capacity

    (kVA)

    Current

    (A)

    Voltage

    (V)

    Frequency

    (Hz)

    Current

    (A)

    Cooling Methods

    Protection

    Weight Net/Gross
    (kg)

    Cubic
    (CBM)

    Frame Code

    110P2

    0.2

    0.25

    0.6

    1.6

     3-Phase

    0-240 (Max.)

    0.1~600

    6.1

    Fan-cooled

    IP 20

     

    NEMA 1

     

    0.0084

    E1-A

    110P4

    0.4

    0.5

    1.2

    3

    11.4

     

    110P7

    0.75

    1

    2

    5

    19.1

     

    111P5

    1.5

    2

    3

    7.5

    28.6

     

    Topvert E1 Series:  1-Phase, 200-240VAC, 50/60 Hz  (Tolerance Range: 180-264V, 47-63Hz)

    Model

    Motor

    (230V, 4 Pole)

    Rated Output

    Power Source

    Enclosure Construction

    E1-xxxxx

    Power

    (kW)

    Horse Power (Hp)

    Capacity

    (kVA)

    Current

    (A)

    Voltage

    (V)

    Frequency

    (Hz)

    Current

    (A)

    Cooling Methods

    Protection

    Weight Net/Gross
    (kg)

    Cubic
    (CBM)

    Frame Code

    210P2

    0.2

    0.25

    0.6

    1.6

     3-Phase

    0-240 (Max.)

    0.1~600

    3

    Fan-cooled

    IP 20

     

    NEMA 1

     1.5/1.8

    0.0084

    E1-A

    210P2A
     
    0.0066
    E1-S

    210P4

    0.4

    0.5

    1.2

    3

    5.7

     1.5/1.9

    0.0084

    E1-A

    210P4A

     
    0.0066
    E1-S

    210P7

    0.75

    1

    2

    5

    9.5

     1.6/1.9

    0.0084

    E1-A

    210P7A

     
    0.0066
    E1-S

    211P5

    1.5

    2

    3

    7.5

    14.3

     1.6/2.0

    0.0084

    E1-A

    211P5A

     
    0.0066
    E1-S

    212P2

    2.2

    3

    4.4

    11

    21

    1.7/2.0

    0.0084

    E1-A


    Topvert E1 Series:  3-Phase, 200-240VAC, 50/60 Hz  (Tolerance Range: 180-264V, 47-63Hz)

    Model

    Motor

    (230V, 4 Pole)

    Rated Output

    Power Source

    Enclosure Construction

    E1-xxxxx

    Power

    (kW)

    Horse Power (Hp)

    Capacity

    (kVA)

    Current

    (A)

    Voltage

    (V)

    Frequency

    (Hz)

    Current

    (A)

    Cooling Methods

    Protection

    Weight Net/Gross
    (kg)

    Cubic
    (CBM)

    Frame Code

    230P4

    0.4

    0.5

    1.2

    3

     3-Phase

    0-240 (Max.)

     

    0.1~600

    3.3

    Fan-cooled

    IP 20

     

    NEMA 1

     1.5/1.9

     
    0.0084

    230P4A

     
    0.0066

    E1-S

    230P7

    0.75

    1

    2

    5

    5.5

     1.6/1.9

    0.0084

    230P7A

     
    0.0066
    E1-S

    231P5

    1.5

    2

    3

    7.5

    8.3

     1.6/1.9

    0.0084

    231P5A

     
    0.0066

    E1-S

    232P2

    2.2

    3

    4.4

    11

    12.1

    1.6/2.0

    0.0084

    233P7

    3.7

    5

    6.8

    17

    18.7

    1.7/2.0

    (235P5)

    5.5

    7.5

    10

    25

    27.5

      

     

    (E1-B)

    (237P5)

    7.5

    10

    13

    33

    36.3

      


    Topvert E1 Series:  3-Phase, 380-460VAC, 50/60 Hz  (Tolerance Range: 342-528V, 47-63Hz)

    Model

    Motor

    (460V, 4 Pole)

    Rated Output

    Power Source

    Enclosure Construction

    E1-xxxxx

    Power

    (kW)

    Horse Power (Hp)

    Capacity

    (kVA)

    Current

    (A)

    Voltage

    (V)

    Frequency

    (Hz)

    Current

    (A)

    Cooling Methods

    Protection

    Weight Net/Gross
    (kg)

    Cubic
    (CBM)

    Frame Code

    430P4

    0.4

    0.5

    1.3

    1.6

     3-Phase

    0-460 (Max.)

    0.1~600

    1.8

    Fan-cooled

    IP 20

     

    NEMA 1

     1.6/1.9

     0.0084

    E1-A

    430P7

    0.75

    1

    2.4

    3

    3.3

     1.6/1.9

    431P5

    1.5

    2

    3.3

    4.2

    4.6

     1.6/2.0

    432P2

    2.2

    3

    4.8

    6

    6.6

    1.6/2.0

    0.0084

    E1-A

    433P7

    3.7

    5

    6.8

    8.5

    9.4

    1.7/2.0

    (435P5)

    5.5

    7.5

    10

    13

    14.3

     

     

    (E1-B)

    (437P5)

    7.5

    10

    14

    18

    19.8

     

    Remark:
    1.Frame code E1-S is compact size of E1-A
    2.(  )means not available.

    Specifications

    Max. Applicable Motor

    Output Range (kW/Hp)

    1- phase, 100 ~ 120VAC, 50/60Hz:0.2 ~ 1.5kW (0.25 ~ 2Hp)

    1- phase, 200 ~ 240VAC, 50/60Hz:0.2 ~ 2.2kW (0.25 ~ 3Hp)
    3-phase, 200 ~ 230VAC, 50/60Hz:0.4 ~ 7.5kW (0.5 ~ 10Hp)
    3-phase,380 ~ 460VAC, 50/60Hz:0.4 ~ 7.5kW (0.5~ 10Hp)
    Output
    Output Frequency
    0.1 ~ 600Hz
    Overload Endurance
    150% of rated current for 1 minute/10minute, Ta <=40 ;200% of rated current for 2 seconds
    Maximum Output Voltage

    Proportional to Input Voltage, 3-Phase (For 100V class, output voltage is twice of the input voltage)

    Power factor / Efficiency

    Power factor no lower than 0.95. Efficiency no lower than 95% at full load

    Control Characteristics
    Control System
    SPWM (Sinusoidal Pulse Width Modulation), V/F control and Sensorless Vector Control selectable
    Speed Control
    V/F Control 1:20; Sensorless Control 1:50

    Frequency Setting Range

    0.10 - 600Hz,programmable

    Frequency Setting Resolution

    0.01Hz/step

    PWM Carrier Frequency

    1kHz - 18kHz Adjustable (Restrictions on some models)

    Torque Characteristics

    Including the auto-torque, auto-slip compensation; starting torque can be 150% at 1.0Hz

    Skip Frequency

    3 points

    Accel/Decel Time

    0.1-6000 seconds (2 Independent settings for Accel/Decel Time

    Stall Prevention Level

    10 to 250%, Setting of Rated Current. Setting range 0.1-600Hz while stop

    DC Braking

    DC Braking Current Level: 0 to 125% of rated output current. DC Braking time: 0 to 60 seconds. Start-Point for DC Braking: 0.1-600Hz both when start up and stop.

    Dynamic Braking Torque

    Approx. 20%,Dynamic Brake chopper built-in.

    V/F Pattern

    Adjustable V/F curve using 4 independent points.

    Operating Characteristics

    Frequency Setting

    Keypad

    By a rotary encoder (setting resolution 0.01Hz/step)

    External Signal

    0 ~ +10VDC (Input impedance 20k Ω ), 4 ~20mA DC ( Input impedance 250 Ω ), Multi-Function Inputs 1 ~ 6 (15 Steps Jog, up/down ), PLC run , (Option) RS-485 serial interface MODBUS protocol

    Operation Setting

    Keypad

    Set by RUN, STOP and JOG key

    External Signal

    FWD, REV, MI1 to MI6 can be combined to offer various modes of operation, (Option) RS-485 serial interface MODBUS protocol

    Multi-Function Input Signal (6 signals)

    Multi-step selection 0 to 15, first to second accel/decel switches, accel/decel inhibit, EF Input, Emergency Stop, auxiliary motor control is invalid, ACI/AVI/AUI speed command selection, Reset, PLC Run , Jog, Up/Down command, Sink/Source selection

    Multi-Function Output Indication( 2 signals, extra 3 signals as option)

    Drive Operating, Frequency Attained, Non-zero, Base Block, Fault Indication, Local/Remote indication, PLC Operation indication, and Auxiliary Motor Output

    Analog Output Signal (option)

    Analog signal output proportional to output frequency, output current, voltage, frequency command or motor's speed.

    Fault Indication

    The output will be activated when faults occur (1 Relay contact point RA, RB, RC. or 2 Open-collector output)
    Communication

    (Option) RS-485 serial interface MODBUS protocol

    Other Functions

    PID feedback control, automatic voltage regulation, Momentary Power Loss restart, S-Curve, External Fault, Fault Reset, Auto Restart, Fault Records, Frequency Limits, Fan & Pump Control, Parameter Lock/Reset, Auto Tuning, Reverse Inhibition, Over-Voltage/ Over-Current Stall Prevention, automatic energy-saving, DC Braking, Speed Search during Start-up, PLC, MODBUS Communication

    Protection

    Self-testing, AC source Over Voltage, Over Voltage, Over Current, Under Voltage, Over Load, Overheating, External Fault, Electronic thermal, Ground Fault, Stall Prevention, Output short circuit , IGBT short circuit

    Digital Keypad

    (Option) PU-02 with Copy Function

    (Option) PU-03 with LCD Display and Operation

    8 Function keys

    Access Run, Stop, Reset/ Digit Shift, Forward/ Reverse run, Display mode, Keypad Enable, Programming data and Jog operation.

    360 degree Rotary Encoder

    Sets the parameter number and changes the numerical data

    6 digits 7 segment display

    Display the Setting frequency/actual operation frequency, Output current/Voltage, User defined unit.

    Six LED Display for status indication
    Display the AC drive's run/stop status, forward/Reverse run status, Keypad enable, and Frequency command source
    Removable Keypad
    Remote control distance up to 150 meters.

    Environmental Conditions

    CE Safety
    Meet LVD: EN50178 standards; When combining with Toptek's filter, meet EMC: EN61800-3 standards
    UL Safety

    Meet UL508C standards

    Temperature
    Ambient: -10°C ~ +40 °C ( Non-Condensing and not frozen ). Storage: -20°C ~ +60°C

    Humidity

    Below 98% R. H. (Non-Condensing)

    Vibration

    Below 20Hz: 1G, above 20Hz: 0.6G

    Installation Location

    Altitude 1,000 m or lower, keep away from corrosive gasses, liquid and dust

    Sitemap AC Motor Drive Manufacturer Frequency Drive Manufacturer